All-In-One AFM Probes

All-In-One

All-In-One

Multipurpose AFM Probe with 4 Different Cantilevers
Coating: none
Tip Shape: Rotated
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    210 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
All-In-One-Al

All-In-One-Al

Multipurpose AFM Probe with 4 Different Cantilevers and Aluminum Reflective Coating
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    210 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
ElectriAll-In-One

ElectriAll-In-One

Multipurpose AFM Probe with 4 Different Cantilevers and Platinum Overall Coating
Coating: Electrically Conductive
Tip Shape: Rotated
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    210 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
All-In-One-DLC

All-In-One-DLC

Multipurpose AFM Probe with 4 Different Cantilevers and Diamond-Like-Carbon Tip Coating
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    200 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
All-In-One-Al-Tipless

All-In-One-Al-Tipless

Multipurpose AFM Probe with 4 Different Tipless Cantilevers
Coating: Reflective Aluminum
Tip Shape: Tipless
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    210 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
All-In-One-Tipless
Best Seller

All-In-One-Tipless

Multipurpose AFM Probe with 4 Different Tipless Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 4
  • F
    15 kHz
  • C
    0.2 N/m
  • L
    500 µm
  • F
    80 kHz
  • C
    2.7 N/m
  • L
    210 µm
  • F
    150 kHz
  • C
    7.4 N/m
  • L
    150 µm
  • F
    350 kHz
  • C
    40 N/m
  • L
    100 µm
All-In-One-DD
Best Seller

All-In-One-DD

Multipurpose AFM Probe with 4 Different Cantilevers and Conductive Diamond Tip Coating
Coating: Conductive Diamond
Tip Shape: Rotated
AFM Cantilever:
  • F
    19 kHz
  • C
    0.5 N/m
  • L
    500 µm
  • F
    110 kHz
  • C
    6.5 N/m
  • L
    210 µm
  • F
    200 kHz
  • C
    18 N/m
  • L
    150 µm
  • F
    450 kHz
  • C
    100 N/m
  • L
    100 µm